DHC-8-402, G-JECG
Report name:
DHC-8-402, G-JECG
DHC-8-402, G-JECG
Registration:
G-JECG
G-JECG
Type:
DHC-8-402
DHC-8-402
Location:
Approximately 10 nm east of Prestwick Airport
Approximately 10 nm east of Prestwick Airport
Date of occurrence:
10 December 2006
10 December 2006
Category:
Public transport - Fixed Wing
Public transport - Fixed Wing
Summary:
During flight in icing conditions, the flight crew experienced multiple flight instrument failures which were consistent with icing of the pitot/static probes. Recorded flight data indicated that the standby pitot/static probe heat switch had not been selected ON prior to flight, and the investigation concluded that, in all probability, the remaining two pitot/static probe heat switches had also not been selected ON. Non-standard checklist procedures and distractions may have created an environment in which the selection of the probe heat switches to ON was missed before takeoff, and not detected until after the icing encounter.
During flight in icing conditions, the flight crew experienced multiple flight instrument failures which were consistent with icing of the pitot/static probes. Recorded flight data indicated that the standby pitot/static probe heat switch had not been selected ON prior to flight, and the investigation concluded that, in all probability, the remaining two pitot/static probe heat switches had also not been selected ON. Non-standard checklist procedures and distractions may have created an environment in which the selection of the probe heat switches to ON was missed before takeoff, and not detected until after the icing encounter.
Download Adobe PDF reader software free from the Adobe Reader website.
Note: Users of Adobe PDF Reader version 5 (and below) may experience problems opening these PDF reports. We recommend that you upgrade to the latest version of Adobe PDF Reader by following the link above.